NovelSat NS300X Módem de Satélite
• Mayor confiabilidad gracias al principio de diseño integrado • Funciona bien en un amplio rango de temperatura • Tamaño razonable y peso liviano • Cumple con los estándares ETSI, FCC
Specification | |||
PARAMETER | DVB-S2/2X | NovelSat NS3/NS4 | Features |
QPSK | 1/4, 13/45*, 1/3, 2/5, 9/20*, 1/2, 11/20*, 3/5, 2/3, 3/4, 4/5, 5/6, 8/9, 9/10 | 1/4, 1/3, 2/5, 13/30, 7/15, 1/2, 8/15, 17/30, 3/5,19/30, 2/3, 32/45, 3/4, 4/5, 5/6, 8/9, 9/10 |
Maximum rate: bidrectional 60 Mbps (2x30 Mbps) Symbol rate:0/1-36Msps |
8APSK | 5/9(L)*,26/45(L)* | DVB-S, DVB-S2, DVB-S/S2 with 5% ROF, DVB-S2X. DVB-DSNG& NovelSat NS4 compliant | |
8PSK | 3/5, 23/36, 2/3, 25/36,13/18*, 3/4, 5/6, 8/9, 9/10 | 2/5, 13/30, 7/15, 1/2, 8/15, 17/30, 3/5, 19/30, 2/3, 32/45, 3/4, 4/5, 5/6, 8/9, 9/10 |
NovelSat DUET CeC (Carrier echo cancellation) techonology - PtP& PtMP IP Enhancements: |
16APSK | 26/45*, 3/5*, 28/45*, 23/36*, 2/3, 25/36*, 13/18*,3/4, 7/9*, 4/5, 5/6, 77/90*, 8/9, 9/10, 1/2(L)*, 8/15(L)*, 5/9(L)*, 3/5(L)*, 2/3(L)* | 2/5, 13/30, 7/15, 1/2, 8/15, 17/30, 3/5, 19/30, 2/3, 32/45, 3/4, 4/5, 5/6, 8/9, 9/10 |
- Bridge mode (Layer 2)/VLAN switching (Layer 2)/Router mode (Layer 3) - IP Encapsulation (NSPE) |
32APSK |
32/45*, 11/15*, 3/4, 7/9*, 4/5, 5/6, 8/9, 9/10, 2/3(L)* | 2/5, 13/30, 7/15, 1/2, 8/15, 17/30, 3/5, 19/30, 2/3, 32/45, 3/4, 4/5, 5/6, 8/9, 9/10 |
- QoS (Quality of Service) - Embedded WAN Acceleration (TCP, Paylord Acceleration) |
64APSK | 11/15*, 7/9*, 4/5*, 5/6*, 32/45(L)* | 19/30, 2/3, 32/45, 3/4, 4/5, 5/6, 8/9, 9/10 |
ACM - Adaptive Coding & Modulation, Up to 1dB/Sec/PtMP configuration AUPC - Automatic Uplink Power Software |
Frame length | 16200. 64800 | 16200. 64800 |
Upgrade OTA - Over The Air: M&C, Software Upgrade Data interdaces: Gbe (1000 Base-T), 4E1/T1, |
ROF |
SRRC 5%, 10%, 15%, 20%, 25%, 35% *DVB-S2X only |
"SRRC Like" 2%, 5%, 10%, 15%, 20%, 25%, 35% |
SFP Carrier ID (CID) compliant |
Modulator RF Ports | Demodulator RF Ports | ||
L-Band | L-Band | ||
Connector | SMA (F) 50 0hm or N-type (F) 50 0hm+24/+48v/ | Connector | F-Type (F) 75 0hm |
Freq. range | 950-2150Mz in 10Hz steps | Frequency range | 950-2150Mz in 10Hz steps |
Power level | -30 to 0 dBm | Signal level | -106+10log(F) (F in MSPS) Max:-20dBm |
Power setting resolution | 0.1dB | Composite power | <-20dBm |
Power accuracy/temp. stability |
±0.5dB/±0.5dB | Return loss | >12dB |
Return loss | >12dB | Max.input level | 0dBm |
Sputious | -55dBc in band and out of band at max power |
LNB power control: Voltage |
11.5-14V (Vert.Pol.), 15\6-19V(Horiz. pol.) |
Phase noise | @100Hz-70dBc, @1KHz-80dBc, @10KHz-85dBc, @100KHz-95dBc, @1MHz-100dBc |
Band Select Max. current |
22KHz±4KHz 350mA |
Additional Information | |||||
PARAMETER | DVB-S2/2X | NovelSat NS3/NS4 | |||
SW interfaces |
Command line interface Web based graphic user interface SNMP V3 |
Weight Size |
4Kq(8.8 lbs) 19"W x18" x 1.75"H 48.3 x 45.7 x 4.45 cm |
Prime power |
100-240 VAC. 50-60Hz -48VDC (option) |
M&C interfaces |
Front panel Serial RS232 GbE 10/100 |
10MHz Clock Stability |
±1.0 ppm over 0°C to 50°C (standart) ±0.03ppm over 0°C to 50°C (option) |
Operating temp. Storage temp. |
0 to 50°C -40°C to 70°C |
Data Interface |
GigaBit 10/100/1000Base-T Up to 4 x E1/T1 Interfaces SFP-(additional GbE\Optical Interface) |
Aging |
±1.0 ppm/year (standart) ±0.03ppm/year (option) |
Operating humidity Storage humidity |
Up to 85% Non-Condensing Up to 85% Non-Condensing |
Download the Specification in PDF Format | |||
UHP Networks UHP-IPS Broadband Satellite Router |
|||