Input Parameters |
Input Frequency |
3.4 to 4.2GHz |
Impedance |
50Ω |
VSWR |
1.3:1 |
|
|
Transfer Parameters |
Output Frequency |
950-1750MHz (for C to L) |
|
70 ± 18MHz (140MHz optional) (for C to IF) |
Impedance |
50Ω |
VSWR |
1.5:1 |
Output Power @P1dB |
+5dBm min |
Transfer Parameters |
|
Frequency spectrum |
User selectable (for C to IF) |
Conversion Gain |
45dB min |
Gain Adjustment |
40dB with 0.5dB step |
Gain Flatness |
±0.75dB over 36MHz Bandwidth |
|
±2dB over Full Bandwidth |
Gain Stability |
±0.25dB over 24hours at constant temperature |
In Band Spurious |
|
Carrier dependent |
-50dBc at max gain |
Carrier Independent |
-60dBm max |
Out Band Spurious exclude LO |
-60dBm max |
Third order intermodulation products |
40dBc @ two carriers 2MHz apart, 8dB back off from Prated for each carrier |
|
|
Phase Noise |
|
@1KHz |
-73dBc/Hz |
@10KHz |
-83dBc/Hz |
@100KHz |
-93dBc/Hz (for C to IF) |
@1KHz |
-75dBc/Hz |
@10KHz |
-85dBc/Hz |
@100KHz |
-95dBc/Hz (for C to L) |
|
|
|
|
Rear Panel Connections |
IF/L Output |
BNC Female (for C to IF) |
|
N-Type Female (for C to L) |
RF Band Input |
SMA Female |
10MHz Ext REF Connector |
BNC Female |
(Optional) |
|
Remote Connector |
DB 9 Female |
Power IN |
AC/DC |
|
|
Monitor and Control |
Interface |
RS232/ RS485/ SNMP (Optional) |
Monitoring parameters |
LO & Temperature Alarms |
Control Parameters |
Gain Adjustment @ 0.5dB Step |
|
|
Power Supply |
AC Input Voltage |
100 to 240VAC 50/60Hz |
Power Consumption |
35W |
|
|
Environmental |
Operating temperature |
0ºC to 50ºC |
Humidity |
up to 95% (Non-condensing) |
|
|
Mechanical |
Dimension |
480L x 330W x 44H mm |
Weight |
3.5kg (for C to L) |
|
4.0kg (for C to IF) |
|
|
Compliance Standard |
Inquire |
|
|