Bienvenido a IK Tech Corporation
Su única parada para todas sus necesidades de satélites

AGILIS AUC48 Serie SI/L de Banda para la Banda X del Convertidor

Convertidor de IF/L-Band a X-Band Up serie AGILIS AUC48

IKtechcorp es el distribuidor del satélite Agilis , productos de comunicación vsat. LNB, BUC, amplificador de línea, filtro, aislador, controlador de unidad, RF

El AUC48 es una nueva y rentable serie de convertidores. Estos convertidores se pueden configurar mediante un árbol de menú intuitivo desde un panel frontal LCD. Estos convertidores vienen en un rack estándar de 19 ”de 1RU de altura.

Código: agilisAUC48_Upconverter

AGILIS AUC48 Series IF/L-Band to X-Band Up Converter

Agilis ACU 48 Series IL/F-Band to X-Band Up Converter Frequency Image Picture
Summary

The AUC48 is a new, cost effective series of Converters. These converters can be configured using an intuitive menu tree from a LCD front panel. These converters come in a standard 19” Rack of 1RU height.

 
Features
• Compact unit, complete in a single 1 RU package
• Full monitoring and control through LCD and
keypad front panel or serial remote
• User selectable spectrum inversion
• Redundant ready
• Available for wide satellite bands
• Flexible design for various user’s configurations
• RS232, RS485 and SNMP interface for remote M&C
 
Quality Assurance
All Agilis IDUs are designed and manufactured according to ISO 9001 Standard.
 
Reliability
Field proven with system deployed worldwide, Agilis IDU can withstand temperature from 0ºC to +50ºC up to 95% non-condensing humidity.

AGILIS AUC48 Series IF/L-Band to X-Band Up Converter Specifications

Input Parameters

Input Frequency

950-1700MHz (for L to X)

 

70 ± 18MHz (140MHz optional) (for IF to X)

Impedance

50Ω

VSWR

1.5:1

 

Output Parameters

Output Frequency

7.9 to 8.4GHz

Impedance

50Ω

VSWR

1.5:1

Output Power @P1dB

+5dBm min

 

Transfer Parameters

Frequency spectrum

User selectable (for IF to X)

Conversion Gain

25dB min

Gain Adjustment

20dB with 0.5dB step

Gain Flatness ±0.75dB over 36MHz Bandwidth
±1.5dB over Full Bandwidth

Gain Stability

±0.25dB over 24hours at constanttemperature

In Band Spurious

 

Carrier dependent

-55dBc at max gain

Carrier Independent

-70dBm max

Out Band Spurious exclude LO

-50dBm max

Third order intermodulation products

35dBc @ 2 carriers 2MHz apart, 8dB back off from Prated for each carrier

Phase Noise

 

@1KHz

-73dBc/Hz

@10KHz

-83dBc/Hz

@100KHz

-93dBc/Hz (for IF to X)

@1KHz

-75dBc/Hz

@10KHz

-85dBc/Hz

@100KHz

-95dBc/Hz (for L to X)

 

Rear Panel Connections

IF/L Output

BNC Female (for X to IF)

 

N-Type Female (for L to X)

RF Band Input

SMA Female

10MHz Ext REF Connector

BNC Female

(Optional)

 

Remote Connector

DB 9 Female

Power IN

AC/DC

 

Monitor and Control

Interface

RS232/ RS485/ SNMP (Optional)

Monitoring parameters

LO & Temperature Alarms

Control Parameters

Gain Adjustment @ 0.5dB Step

 

Power Supply

AC Input Voltage

100 to 240VAC 50/60Hz

Power Consumption

35W

 

Environmental

Operating temperature

0ºC to 50ºC

Humidity

up to 95% (Non-condensing)

 

Mechanical

Dimension

480L x 330W x 44H mm

Weight

3.5kg (for C to L)

 

4.0kg (for C to IF)

 

Compliance Standard

Inquire