GENERAL
|
|
|
Approvals |
UL, CE |
Regeneration Method |
Automatic, demand |
Maximum dew point |
-40˚ F/C |
|
|
ENCLOSURE
|
|
|
Dimensions |
17″ × 12″ × 5-1/4″ (432mm × 305mm × 133mm) |
Weight |
16 lbs (7.26 kg) |
Mounting |
Dual-post rack, flush mounted Single-post rack, center mounted Wall mounted |
|
|
POWER
|
|
|
Supply |
±20-75 VDC Power Supply Option |
Maximum current |
1.0 Amps at 100 V |
Power usage |
40 W typical, 100 W max |
Heat dissipation |
100 BTU/hr typical, 325 BTU/hr max |
|
|
OUTPUT
|
|
|
Flow rate |
25.4 scfh (12 lpm) |
Maximum pressure |
7.5 psig (517mbar) |
Internal safety relief valve |
8 psig (552mbar) |
Discharge port |
1/8″ NPT 3/8″ or 1/4″ hose barb (both included) |
Display units |
SI (millibars); English (psig), default |
|
|
CONTROL
|
|
|
Protocols |
HTTP (Web Interface), SNMP, UDP, TFTP |
Maximum pressure |
Confi gurable Range: 0.20 psig – 7.5 psig (14mbar – 517mbar), Default: 0.50 psig (34.5mbar) |
Minimum pressure |
Confi gurable Range: 0.10 psig – 7.4 psig (7mbar – 510mbar), Default: 0.30 psig (21mbar) |
Low pressure alarm level |
User Configurable, Default: 0.15 psig (10mbar) |
High pressure alarm level |
User Configurable, Default 1.5 psig (103.5mbar) |
Alarm relays |
Contact Type – Form C, SPDT, reverse acting Ratings – 0.25 Amps @ 60 V User configurable, Defaults:
- Alarm Relay 1: Summary Alarm
- Alarm Relay 2: Low Pressure Alarm
- Alarm Relay 3: Over Pressure Alarm
|
Duty cycle alarm |
User configurable, Default: 50% |
Master/Slave configuration |
User configurable, Default: Standard/Slave |
|
|
ENVIRONMENTAL
|
|
|
Operating temperature |
32°F to 130°F (0°C to 55°C) |
Storage temperature |
−40°F to 150°F (−40°C to 60°C) |
|
|
Diagrams
|
|
|
|
|
|
|
Compliance Standard
|
Inquire
|
|