MIL-SPEC CONNECTORS, TYPE 2 |
|
|
|
Position |
Color |
AC Connections |
DC Connections |
|
|
|
|
1 |
GREEN |
GROUND |
GROUND |
2 |
BLACK |
LINE |
POSITIVE |
3 |
WHITE |
NEUTRAL |
NEGATIVE |
|
|
|
Position |
Internal Port Type |
Destination Pin |
Function |
Color |
|
|
|
|
|
A |
RS422A |
3 |
RX + |
BROWN |
B |
RS422A |
4 |
TX + |
ORANGE |
C |
RS422A |
6 |
TX - |
YELLOW |
D |
ALARM |
1 |
Relay 1 close on alarm |
TAN |
E |
ALARM |
2 |
Relay 1 open on alarm |
PINK |
F |
ALARM |
3 |
Relay 2 close on alarm |
DARK BLUE |
G |
ALARM |
4 |
Relay 2 common |
WHITE/BLACK |
H |
ALARM |
5 |
Relay 2 open on alarm |
WHITE/RED |
J |
RS232 |
2 |
TX |
LIGHT BLUE |
K |
RS232 |
3 |
RX |
VIOLET |
L |
RS232 |
8 |
RTS |
GREY |
M |
|
|
+5V (from RS422A PIN 2) |
RED |
N |
|
|
Ground (from RS422A PIN 1) |
BLACK |
P |
RS422A |
9 |
RX - |
GREEN |
R |
ALARM |
9 |
Relay 1 common |
WHITE/GREEN |
S |
ALARM |
10 |
Relay 3 common |
WHITE/YELLOW |
T |
ALARM |
11 |
Relay 3 open on alarm |
WHITE/BLUE |
U |
RS232 |
7 |
CTS |
WHITE |
V |
ALARM |
12 |
Relay 3 close on alarm |
WHITE/BROWN |
|
|
|
GENERAL |
|
|
Approvals |
UL, CE |
Regeneration Method |
Automatic, demand |
Maximum dew point |
-40˚ F/C |
|
|
ENCLOSURE |
|
|
Type |
Hoffman® POLYPRO® Polyester Type 4X |
Cover Attachment |
Hinged, lockable |
Protection |
IP66, NEMA 4X |
Dimensions |
15.31″ × 18.06 ” × 9.25 ” (389mm × 459mm × 235mm) |
|
|
Entries |
|
1 x 0.88″ (22mm) |
entry for supply power
|
2 x 0.63″ (16mm) |
entry for dry pressurized air and condensate discharge |
|
|
Weight |
24 lbs (10.9 kg) |
Mounting |
Wall, post/pole or shelf mounted |
|
|
POWER |
|
|
Supply |
±20-75 VDC |
Maximum current |
1.0 Amps at 100 V |
Power usage |
40 W typical, 100 W max |
|
|
OUTPUT |
|
|
Flow rate |
25.4 scfh (12 lpm) |
Maximum pressure |
7.5 psig (517mbar) |
Internal safety relief valve |
8 psig (552mbar) |
Discharge port |
1/8″ NPT /
3/8″ or 1/4″ hose barb (both included) |
Display units |
SI (millibars); English (psig), default |
|
|
CONTROL |
|
|
Protocols |
HTTP (Web Interface), SNMP, UDP, TFTP |
Maximum pressure |
Confi gurable Range: 0.20 psig – 7.5 psig (14mbar – 517mbar), Default: 0.50 psig (34.5mbar) |
Minimum pressure |
Confi gurable Range: 0.10 psig – 7.4 psig (7mbar – 510mbar), Default: 0.30 psig (21mbar) |
Low pressure alarm level |
User Configurable, Default: 0.15 psig (10mbar) |
High pressure alarm level |
User Configurable, Default 1.5 psig (103.5mbar) |
Alarm relays |
Contact Type – Form C, SPDT, reverse acting
Ratings – 0.25 Amps @ 60 V
User configurable, Defaults:
- Alarm Relay 1: Summary Alarm
- Alarm Relay 2: Low Pressure Alarm
- Alarm Relay 3: Over Pressure Alarm
|
Duty cycle alarm |
User configurable, Default: 50% |
Master/Slave configuration |
User configurable, Default: Standard/Slave |
|
|
ENVIRONMENTAL |
|
|
Operating temperature |
−40°F to 130°F (0°C to 55°C) |
Storage temperature |
−40°F to 150°F (−40°C to 60°C) |
|
|
Diagrams |
|
|
|
|
Compliance Standard |