TYPICAL SPECIFICATIONS
|
|
|
RF Frequency |
5.85 to 6.425 GHz (Standard C-band) |
IF Frequency |
950 to 1,525 MHz |
Local Frequency |
4.90 GHz |
Output Interface |
Waveguide, CPR137 |
Input Interface |
F-type, female (75 ohm)
|
Output Power @ 1 dB G.C.P. |
+40 dBm min. over temperature |
Linear Gain |
64 dB nom., 58 dB min. |
|
|
Requirement for External Reference ▼ |
|
Frequency |
10 MHz (sine-wave) |
Input Power |
-5 to +5 dBm @ Input port |
|
|
Phase Noise |
|
@ 100 Hz |
-125 dBc/Hz max. |
@ 1 kHz |
-135 dBc/Hz max. |
@ 10 kHz |
-140 dBc/Hz max. |
|
|
L.O. Phase Noise |
|
@ 100 Hz |
-60 dBc/Hz max. |
@ 1 kHz |
-70 dBc/Hz max. |
@ 10 kHz |
-80 dBc/Hz max. |
@ 100 kHz |
-90 dBc/Hz max. |
|
|
Receive Band Noise Density |
-87 dBm/4kHz max. |
Input V.S.W.R. |
2.0 : 1 max. |
Output V.S.W.R. |
2.0 : 1 max. |
Power Requirement |
90 to 264 VAC [AC Power Oparating] |
Power Consumption |
69 W typ., 75 W max. |
Mute |
Shut off the HPA in case of L.O. unlocked or no 10 MHz reference signal. |
LED Indicator |
GREEN: L.O. locked / RED: L.O. unlocked or no 10 MHz reference signal |
Port for Voltage Input |
IF Connector supplied by 150W AC/DC PSU throught IF Cable |
|
|
Mechanical & Environmental ▼ |
|
Temperature Range (ambient) |
-40 to +55 C (operating) -40 to +75 C (storage) |
Dimension & Housing ( without Interface Connectors ) |
219.5 mm (L) x 175 mm (W) x 99 mm (H) [8.64” (L) x 6.89” (W) x 3.90” (H)] |
Weight |
3.2 kg [7.0 lbs] |