MITEC 60-80W C-BAND ONE-BOX-DESIGN BUC
60-80 C-BAND ONE-BOX-DESIGN BUC
The new generation of Mitec VSAT Block Up-Converters comes with an integrated BUC/Booster package and designed for high efficiency resulting in an optimal compact form factor and lightweight with high performance and reliability. With the advanced customer interface and HTTP embedded web page, the operator is able to monitor and control the BUC and the System redundancy from a web browser.
- Compact size and light weight
- Offered in 5 C-Bands
- Band 1: Standard 5.850-6.425 GHz
- Band 2: Super Extended 5.850-6.725 GHz
- Band 3: Low Extended 5.725-6.425 GHz
- Band 4 INSAT: 6.725-7.025 GHz
- Band 5: Palapa: 6.425-6725 GHz
- Best in Class efficiency with less than 420W draw for 60W RF Output and 460W draw for 80W RF Output
- Easy to install
- High thermal dissipation efficiency resulting in "Best in Class" Mean Time Before Failure (MTBF)
- Superior phase noise, 5 dB better than IESS 308 /309
- 1:1 switching logic built into the BUC eliminating expensive external controller
- Built-in facilities for critical parameters such as: RF power detection, mute control, over temperature shutdown, summary alarm
- HTTP Hosting
- SNMP
- TELNET through TCP/IP
- RS485, RS232, Ethernet and Dry-Contacts M&C interface
MAIN CHARACTERISITICS OF C-BAND BUCs | ||||
Power (W) | 60 W | 80 W | ||
Power (P1 dB) min.(dBm) | 48 | 49 | ||
Gain min.(dB) | 75 | |||
M&C | Dry Contacts, RS485, RS232, Ethernet | |||
Power Consumption (at rated power) | 420 W | 460 W | ||
Power Voltage (VDC) | 110/200 VAC, 48 VDC | |||
Cooling | Forced Air | |||
Dimensions (L x W x H) | 12.0 x 7.7 x 7.0 inches (304.8x 195.58 x 177.80 mm) | |||
Weight (kg/lbs) | 27.5/12.5 | |||
Output Frequency Range | Band 1: 5.850-6.425 MHz; Band 2: 5.850-6.725 GHz Band 3: 5.725-6.425 GHz; Band 4: 6.725-7.025 GHz Band 5: 6.425-6.725 GHz |
|||
Input Frequency Range | Band 1: 950-1525 MHz; Band 2: 950-1825 MHz Band 3: 950-1675 MHz; Band 4: 1275-1575 MHz Band 5: 975-1275 MHz |
|||
LO Frequency | Bands 1 & 2 : 4.90 GHz Band 3: 4.75 GHz Bands 4 & 5: 5.45 GHz |
|||
TX Gain Stability over temperature range | Bands 1, 4 & 5: ± 1.5 dB max. Bands 2 & 3: ± 2.0 dB max. |
|||
Gain Flatness @ fixed temperature | Over full band: Bands 1, 4 & 5: ± 2.0 dB Band 2 : ± 2.50 dB Band 3: ± 2.25 dB Over 40 MHz: ± 0.5 dB for all bands |
|||
10 MHz Reference (via IF Connector) | 0 dBm ± 5 dB, (internal reference, optional) | |||
L.O. Phase Noise | 5 dB better than IESS 308/309 | |||
Input IF Impedance | 50 Ohms (75 Ohms optional) | |||
Mute Internally Built | Shut off BUC in case of L.O. unlocked | |||
Status LED | Bicolor: RED - Alarm; GREEN - Operational) |