Welcome to IK Tech Corporation
Your one stop for all your satelite needs

AGILIS AUC48 Series X-Band to IF/L-Band Down Converter

AGILIS AUC48 Series X-Band to IF/L-Band Down Converter

IKtechcorp is the distributor for Agilis satellite, vsat communication products. LNB, BUC, Line Amplifier, Filter, Isolator, Unit Controller, RF

The AUC48 is a new, cost effective series of Converters. These converters can be configured using an intuitive menu tree from a LCD front panel. These converters come in a standard 19” Rack of 1RU height.

Product Code: agilisAUC48_Downconverter

AGILIS AUC48 Series X-Band to IF/L-Band Down Converter

Agilis ACU 48 Series X-Band to IF/L-Band Down Converter Frequency Image Picture

Summary

The AUC48 is a new, cost effective series of Converters. These converters can be configured using an intuitive menu tree from a LCD front panel. These converters come in a standard 19” Rack of 1RU height.

 
Features
• Compact unit, complete in a single 1 RU package
• Full monitoring and control through LCD and
keypad front panel or serial remote
• User selectable spectrum inversion
• Redundant ready
• Available for wide satellite bands
• Flexible design for various user’s configurations
• RS232, RS485 and SNMP interface for remote M&C
• Built-in Redundancy control
 
Quality Assurance
All Agilis IDUs are designed and manufactured according to ISO 9001 Standard.
 
Reliability
Field proven with system deployed worldwide, Agilis IDU can withstand temperature from 0ºC to +50ºC up to 95% non-condensing humidity.

AGILIS AUC48 Series X-Band to IF/L-Band Down Converter Specifications

Output Parameters

Output Frequency

950-1700MHz (for X to L) (depends on frequency bands selection)

 

70 ± 18MHz (140MHz optional) (for X to IF)

Impedance

50Ω

VSWR

1.5:1

Input Power

+5dBm min

 

Input Parameters

Input Frequency

7.25 to 7.75GHz

Impedance

50Ω

VSWR

1.5:1

 

Transfer Parameters

Frequency spectrum

User selectable (for IF to C)

Gain Flatness

±0.75dB over 36 MHz Bandwidth

 

±1.5dB over Full Bandwidth

Gain Stability

±0.25dB over 24 hours at constanttemperature

In Band Spurious

 

Carrier dependent

-55dBc at max gain

Carrier Independent

-70dBm max

Out Band Spurious exclude LO

-50dBm max

Third order intermodulation products

35dBc @ 2 carriers 2MHz apart, 8dB backoff from Prated for each carrier

Phase Noise

 

@1KHz

-73dBc/Hz

@10KHz

-83dBc/Hz

@100KHz

-93dBc/Hz (for X to IF)

@1KHz

-75dBc/Hz

@10KHz

-85dBc/Hz

@100KHz

-95dBc/Hz (for X to L)

 

Rear Panel Connections

IF/L Output

BNC Female (for X to IF)

 

N-Type Female (for X to L)

RF Band Input

SMA Female

10MHz Ext REF Connector

BNC Female

(Optional)

 

Remote Connector

DB 9 Female

Power IN

AC/DC

 

Monitor and Control

Interface

RS232/ RS485/ SNMP (Optional)

Monitoring parameters

LO & Temperature Alarms

Control Parameters

Gain Adjustment @ 0.5dB Step

 

Power Supply

AC Input Voltage

100 to 240VAC 50/60Hz

Power Consumption

35W

 

Environmental

Operating temperature

0ºC to 50ºC

Humidity

up to 95% (Non-condensing)

 

Mechanical

Dimension

480L x 330W x 44H mm

Weight

3.5kg (for C to L)

 

4.0kg (for C to IF)

 

Compliance Standard

Inquire