TYPICAL SPECIFICATIONS |
|
|
RF Frequency |
13.75 to 14.5GHz (Universal Ku-band) |
IF Frequency |
950 to1,700 MHz |
Local Frequency |
12.80 GHz |
Output Interface |
Waveguide, WR75 (with Groove) |
Input Interface |
N-type, female (50 ohm) |
Output Power @ 1 dB G.C.P. |
+39 dBm min. over temperature |
Linear Gain |
65 dB nom., 59 dB min. |
IM3 |
-28 dBc typ., -24 dBc max. @ total power ≦ Pout – 3dB |
ACPR |
-28 dBc typ. @ Pout ≦ Pout – 1dB |
Gain Stability Over Temperature |
2 dBp-p typ., 5 dBp-p max. |
Gain Variation Over Frequency |
5 dBp-p max. over 500 MHz / 2 dBp-p max. over 36 MHz |
|
|
L.O. Phase Noise ▼ |
|
@ 100 Hz |
-60 dBc/Hz max. |
@ 1 kHz |
-70 dBc/Hz max. |
@ 10 kHz |
-80 dBc/Hz max. |
@ 100 kHz |
-90 dBc/Hz max. |
@ 1 MHz |
-100 dBc/Hz max. |
|
|
Input V.S.W.R. |
2.0 : 1 max. |
Output V.S.W.R. |
2.0 : 1 max. |
Power Requirement
|
+18 to +60 VDC
|
Power Consumption @ No IF Signal |
65 W typ. |
Power Consumption @ P1dB |
90 W max. |
Mute |
Shut off the HPA in case of L.O. unlocked or no 10 MHz reference signal. |
LED Indicator |
GREEN: L.O. locked / RED: L.O. unlocked or no 10 MHz reference signal |
M&C Function |
FSK Modulation M&C: Power Monitor / TX On/Off Control / Alarm … etc
|
|
|
Mechanical & Environmental ▼ |
|
Temperature Range (Operating) |
-40 to +75 C (Operation Guarantee) -40 to +55 C (Performance Guarantee)
|
Temperature Range (Storage) |
-40 to +75 C |
Dimension & Housing |
180 (L) x 130 (W) x 80 (H) mm [7.09” (L) x 5.12” (W) x 3.15” (H)] without interface connector and screws |
Weight |
2.4 kg max. [5.3 lbs max.] |