Welcome to IK Tech Corporation
Your one stop for all your satelite needs

VIKING ETI-ADH-NETCOM (24658) Automatic Air Dehydrator with Ethernet Communications AC Power - w/DISPLAY

VIKING ETI-ADH-NETCOM (24658) Automatic Air Dehydrator with Ethernet Communications AC Power - w/DISPLAY

VIKING ETI-ADH-NETCOM (24658) Automatic Air Dehydrator with Ethernet Communications AC Power - w/DISPLAY

IKtechcorp is the distributor for Viking SATCOM, a leading manufacturer and supplier of commercial satellite equipment. Viking SATCOM offers a wide range of products used in the VSAT, DTH, COTM, Mobile, TVRO, Educational, Teleport, Cable, and Broadcast industries. Satellite, DTH, VSAT, Flyaway, quick deploy, receive only, earth station, RF, prodelin, motorized auto point, vehicle antennas. Also featuring beacon receivers, de-icing systems, dehydrators, feeds, filters, mountss, redundant systems, snow covers etc.

• Rack Mount Configuration with Front Display Panel Option
• 100-240 VAC, 50/60 Hz Power Supply Option
• The Environmental Technology ADH NETCOM automatic dehydrator supplies low pressure air to keep waveguide and coaxial cable dry to ensure signal quality
• Highly configurable to meet the needs of wide ranging application
• Programmable operating pressure range: 0.10 psig - 7.50 psig (7mbar - 517mbar)
• Brushless compressor for long life
• Future proof software based features allow updates and upgrades while in service
• Remote monitoring and control with web interface or SNM
• Ethernet, RS-422/485, RS-232 and alarm relay outputs for compatibility with nearly any system

Product Code: VIKING_ETI-ADH-NETCOM_24658

VIKING ETI-ADH-NETCOM (24658) Automatic Air Dehydrator with Ethernet Communications AC Power - w/DISPLAY

VIKING ETI-ADH-NETCOM Automatic Air Dehydrator with Ethernet Communications - RACK MOUNT Product Picture, Price, Image, Pricing
 

Summary

VIKING ETI-ADH-NETCOM Automatic Air Dehydrator with Ethernet Communications

Waveguide Dehydrator: ADH NETCOM
The ADH NETCOM automatic waveguide dehydrator supplies low pressure dry air to keep waveguide and coaxial cable dry. Output pressure is configurable between 0.10 psig and 7.50 psig (7mbar – 517mbar) in 0.01 psig (0.67mbar) increments. Factory default pressure is 0.5 psig (34.5mbar). Operational monitoring and alarms are software based making them highly configurable in the field. Future software features can be installed while in service over the internet or local Ethernet network.

Network-ready
The ADH NETCOM automatic dehydrator is Ethernet network ready. Units can be configured and monitored using either built in SNMP support or the web interface. Legacy system support is provided via RS-422/485 or RS-232 interfaces. Three programmable alarm relays are also included. Communicated operational information includes output pressure, duty cycle, temperature, compressor hours and air drying canister status.

The ADH NETCOM automatic dehydrator uses a brushless dual-diaphragm pump for long life. Dehydrator operates with exceptionally low noise and vibration levels. The air drying canisters use aluminum oxide desiccant for high efficiency. The humidity sensor signals for regeneration based upon current dew point rather than at fixed time intervals for additional energy savings and long desiccant life.

The ADH NETCOM automatic dehydrator requires only 5-1/4″ (3-U) of rack space and is just 12″ (304.8mm) deep. Mounting hardware allows for fl exible installation options including dual- and single-post rack mounting and wall mounting. The standard unit weighs just 16 lbs (7.26 kg).

The ADH NETCOM automatic dehydrator operates from 100-240 VAC, 50/60 Hz. The dehydrator consumes a maximum of 100 watts during regeneration and approximately 40 watts otherwise. Heat dissipated is up to 325 BTU/hr during regeneration and approximately 100 BTU/hr otherwise. This product creates an exceptionally low heat load for an automatic dehydrator.

Optional Front Panel Display
An optional front panel with display allows for IP configuration and status monitoring when no network is available.

VIKING ETI-ADH-NETCOM Automatic Air Dehydrator Features:

Provides dry pressurized air to ensure signal quality of antenna waveguide and dielectric coaxial cable
Highly configurable to meet the needs of wide ranging applications
Programmable operating pressure range: 0.10 psig - 7.50 psig (7mbar - 517mbar)
Brushless compressor for long life
Future-proof software based features allow updates and upgrades while in service
Remote monitoring and control with web interface or SNMP
Configurable Master/Slave operation
Ethernet, RS-422/485, RS-232 and alarm relay outputs for compatibility with nearly any system
Optional front panel with display allows for IP configuration and status monitoring when no network is available
Simple power connections for 100-240 VAC
Small, light weight chassis with multiple mounting options makes installation easy
Low energy use minimizes operational costs
Quiet operation

 

Configuration
 
VIKING ETI-ADH-NETCOM Automatic Air Dehydrator Conversion from rack mount to wall mount unit
 
Rack Mounting: The dehydrator is equipped with positions for either flush-mounting (for dual-post racks and enclosures) or center-mounting (for single-post racks).
   
Wall Mounting Configuration: To configure the dehydrator for wall mount installation, remove the front panel and the portion of the vented cover with the ETI logo. Reinstall the front panel so that it will be in the new front position once the dehydrator is oriented for wall mounting.
   
Wall Mounting: Ensure the mounting surface and hardware are suitable tosupport a static load of approximately four times the weightof the unit, or 64 pounds (29 kg). Use four appropriate 5/16"mounting hardware to fasten the unit and ensure stable mounting. The dehydrator is equipped with 4 brackets for wall mounting

VIKING ETI-ADH-NETCOM (24658) Automatic Air Dehydrator with Ethernet Communications AC Power - w/DISPLAY

 

GENERAL

   
Approvals UL, CE
Regeneration Method Automatic, demand
Maximum dew point -40˚ F/C
 

ENCLOSURE

   
Dimensions 17″ × 12″ × 5-1/4″ (432mm × 305mm × 133mm)
Weight 16 lbs (7.26 kg)
Mounting Dual-post rack, flush mounted
Single-post rack, center mounted
Wall mounted
 

POWER

   
Supply 100-240 VAC, 50/60 Hz 
Maximum current 1.0 Amps at 100 V
Power usage 40 W typical, 100 W max
Heat dissipation 100 BTU/hr typical, 325 BTU/hr max
 

OUTPUT

   
Flow rate 25.4 scfh (12 lpm)
Maximum pressure 7.5 psig (517mbar)
Internal safety relief valve 8 psig (552mbar)
Discharge port 1/8″ NPT 
3/8″ or 1/4″ hose barb (both included)
Display units SI (millibars); English (psig), default
 

CONTROL

   
Protocols HTTP (Web Interface), SNMP, UDP, TFTP
Maximum pressure Confi gurable Range: 0.20 psig – 7.5 psig (14mbar – 517mbar), Default: 0.50 psig (34.5mbar)
Minimum pressure Confi gurable Range: 0.10 psig – 7.4 psig (7mbar – 510mbar), Default: 0.30 psig (21mbar)
Low pressure alarm level User Configurable, Default: 0.15 psig (10mbar)
High pressure alarm level User Configurable, Default 1.5 psig (103.5mbar)
Alarm relays Contact Type – Form C, SPDT, reverse acting 
Ratings – 0.25 Amps @ 60 V 
User configurable, Defaults:
  • Alarm Relay 1: Summary Alarm
  • Alarm Relay 2: Low Pressure Alarm
  • Alarm Relay 3: Over Pressure Alarm
Duty cycle alarm User configurable, Default: 50%
Master/Slave configuration User configurable, Default: Standard/Slave
 

ENVIRONMENTAL

   
Operating temperature 32°F to 130°F (0°C to 55°C)
Storage temperature −40°F to 150°F (−40°C to 60°C)
 