欢迎来到 IK Tech Corporation
一站式满足您所有的卫星需求

Foxcom Platinum IF Band PL7330T [PL7330T1550]/PL7330R10 Link High Power Input, 10dB Optical Budget

Foxcom Platinum IF Band PL7330T [PL7330T1550]/PL7330R10 Link High Power Input, 10dB Optical Budget

Foxcom Platinum IF Band PL7330T [PL7330T1550]/PL7330R10 链路高功率输入,10dB 光预算

IKtechcorp 是Foxcom Communications Fiber Optic Systems 的分销商,商业卫星设备的领先制造商和供应商。Foxcom 提供广泛的光纤链路,用于 VSAT、DTH、COTM、电信、电缆和广播行业。卫星、DTH、VSAT、光学、光纤,射频。”/></p> • IF 频段:10–200 MHz<br /> • 超过 25 公里的距离[使用 PL7330T1550 为 40 公里]<br /> • 通过前面板 LCD 和机架安装的 SNMP 提供强大的管理功能<br /> • 用户控制和设置所需的 IMD 级别<br /> • 各种射频和光连接器<br /></div>
                
                <div class=

型号: Foxcom_PL7330R10

Foxcom Platinum IF Band PL7330T [PL7330T1550]/PL7330R10 Link High Power Input, 10dB Optical Budget

Foxcom Platinum IF Band PL7330T [PL7330T1550]/PL7330R10 Link High Power Input, 10dB Optical Budget
 
Summary

Foxcom Platinum IF Band PL7330T [PL7330T1550]/PL7330R10 Link High Power Input, 10dB Optical Budget

Foxcom’s Platinum IF products are designed to meet the increasing demand for modularity and high-performance in a small form factor for superior long-distance transmission. With high RF input power and wide dynamic range, the link is designed to provide full specification service up to a full 4 dB optical budget with thePL7330R4 and 10 dB optical budget with the PL7330R10 receiver.

Utilizing Foxcom’s DigiRF technology, the user has full control of all important functions for setup, operation, and analysis via the front panel LCD or via the associated subrack SNMP capability.

In addition IMizer, an automated adjustable link calibration embedded system enables the user to align the RF links IMD/CNR to specific linearity performances without a two-tone test. Select the desired IMD for the optical transmitter, either locally or remotely, IMizer automatically adjusts the laser drive to meet the IMD requirements. 

Each low profile individual transmitter or receiver can be “hot swapped” in the subrack chassis maintaining a best subsystem uptime capability. Each module contains an individual processor to maximize specification performance at all times under demanding user applications.

The PL7330T transmitters and PL7330R4/R10 receivers are designed for subrack chassis mounting. The associated Platinum chassis, model PL7010, has 12 active slots, one main control processor (MCP) slot and two redundant power supplies. No fans are required even under full subrack loading and full LNB powering.

 

     
Order Diagram - Options    
Foxcom Gold Series Order Diagram - Options

Foxcom Platinum IF Band PL7330T [PL7330T1550] / PL7330R10 Link High Power Input, 10dB Optical Budget

 

RF Specifications Units Typical Minumum Maximum
         
Frequency Range - Bandwidth MHz 10 - 200   -
Amplitude Response @any Unity Gain
10 – 200 MHz
any 36 MHz

dB

±0.25
±0.2
.
±0.25
±0.2
Gain Stability dB/24hr ± 0.2   ± 0.25
Gain Variation over temperature dB   -2 2
SFDR1 dB/Hz 103    
SFDR2 dB/Hz 99    
DR (Dynamic Range - single channel)3 dB     30
CNR [any 1 MHz] 2 dB 70 67 73
Noise Figure (NF)1 dB 27   30
Noise Figure (NF)2 dB 13   15
Output IP3 (OIP3)4 dBm - +15 +20
Group Delay Variation- linear @
10 to 30 MHz
30 to 200 MHz
ns
<3.0
<1.0
   
Input/Output Impedance Ohm 50 or 75    
1 dB Compression Point dBm 2   3
Phase Noise5 None      
Third Order InterModulation [IMD]6 dBc   -55 -40
Input Signal Range - Total Power dBm   -30 -5
Maximum Input without Damage       +15
Output Signal Range - Total Power7 dBm   -30 -5
TX/RX Input/Output Return Loss
50 Ohm
75 Ohm
dB
-18
-17
 
-18
-17
Test Port [front panel sample port]8 dB -20 -22 -18
RF Connector
Input/Output
Test Port
Type

F, SMA, BNC, N
F, BNC

         
         
Optical Specifications Units Typical Minimum Maximum
         
Optical Wavelength nm 1310/1550/CWDM    
Optical Power Output mW/dBm 2 / 3 1.7/2.5  
Optical Budget / Distance
10 dB optical budget
dBm/km
1310 nm | 1550 nm
25 | 40
   
RX Optical Input Power dBm
-7

-8
+1
Optical Connector Types Type FC/APC or SC/APC
(E2000 option)
   
Optical Return Loss dB   -60 -55
         
         
Electrical Specifications        
         
Supply Voltage Vdc 12    
Supply Current [TX]9 Amps 0.35    
Supply Current (RX) Amps 0.45    
EMI Rating   EMI Rating: FCC Class B
CE Mark
   
         
         
Physical Specifications        
         
Operating Temperature Range ºC   -10 +55
Storage Temperature Range ºC -45 to +85 -45 +85
Relative Humidity   95% non-condensing    
Altitude ft / Km 10,000 [3.08 ] operating10
14,000 [12.2] non-operating
   
Dimensions [D×W×H] ins/cm 12×0.8×4 / 30.5×2×10.2    
Weight lbs./Kg 0.5 / 0.23    
MTBF Hours TX: 309,481
RX: 359,057
   
MTTR Hours 0.083    
Shock & Vibration  

Designed for normal transportation environment per section MIL-STD-810E. Designed to withstand 20G at 11 ms [½ sine pulse] in non-operating configuration.

     

1.   -5 dBm RF input, link gain = 0 dB, IMD=-40 dBc @ 0 dBm optical input - max. RF input
2.   -30 dBm RF input, link gain = 25 dB, IMD=-40 dBc @ 0 dBm optical input - min.. RF input  
3.   User adjustable
4.   -5 dBm RF in @ IMD=-40 dBc
5.   Direct modulation utilized
6.   Adjustable. Above -10 dBm input min. -50 dBc
7.   Alarm trip point: RED -2 dBm, AMBER -33 dBm
8.   -45 dBm minimum input
9.   Under 10º add 120 mA  for TX [laser heating]