FREQUENCY RANGE | 27.5 to 31.0 GHz |
OUTPUT POWER | |
Traveling Wave | Tube 650W (58.1 dBm) |
RF Output Limit (PLIMIT) @ Flange | 283W (54.52 dBm) to 333W (54.52 dBm) |
Optional: 346W (55.4 dBm) to 415W (56.2 dBm) | |
Linear Power @ Amplifier Flange (PLIN) | 215W (53.33 dBm) |
GAIN | |
Large Signal (minimum) | 70 dB |
Small Signal (minimum) | 70 dB |
Attenuator range (0.1 dB steps) | 30 dB |
Maximum SSG Variation Over | |
Any Narrow Band | 1.0 dB per 250 MHz |
Any 1 GHz Band (maximum) | 2.5 dB |
Slope (maximum) | ± 0.04 dB/MHz |
Stability, 24 hr. (maximum) | ± 0.25 dB |
Stability, Temperature (maximum) | ± 1.0 dB at any frequency |
INTERMODULATION (maximum) with two equal carriers | -25 dBc @ PLIN |
NOISE POWER RATIO | -19 dBc @ PLIN |
HARMONIC OUTPUT (maximum) with optional harmonic filter | -60 dBc |
AM/PM Conversion (maximum) | 2 deg/dB @ PLIN |
NOISE POWER DENSITY (maximum) | |
Transmit Band | -70 dBW/4 kHz |
Receive Band (<21.2 GHz) | -150 dBW/4 kHz |
GROUP DELAY (maximum) | |
Bandwidth | Any 250 MHz |
Linear | 0.01 nS/MHz |
Parabolic | 0.001 nS/MHz2 |
Ripple | 0.25 nS/Pk-Pk |
RESIDUAL AM NOISE (maximum) | -50 dBc to 10 kHz |
-20 (1.5 + logf) dBc 10 to 500 kHz | |
-85 dBc above 500 kHz | |
SPURIOUS (in band) Linear | -60 dBc |
PHASE NOISE (maximum) | |
10 Hz | -80 dBc |
100 Hz | -85 dBc |
1 kHz | -92 dBc |
10 kHz | -102 dBc |
100 kHz | -115 dBc |
1 MHz | -125 dBc |
VSWR | |
Input (maximum) | 1.3:1 |
Output (maximum) | 1.3:1 |
PRIME POWER | |
100 to 264 VAC | |
47 to 66 Hz, Single Phase | |
1800 VA Typical | |
0.95 Min. Prime Power Factor | |
ENVIRONMENT | |
NONOPERATING TEMPERATURE RANGE | -50°C to +70°C |
OPERATING TEMPERATURE RANGE | -40°C to +60°C |
HUMIDITY | Up to 100% Condensing |
ALTITUDE | 10,000 feet MSL maximum with standard adiabatic derating |
SHOCK AND VIBRATION | Normal Transportation |
COOLING | Liquid Cooled |