AGILIS ALB229 160W Ku-Band VSAT Outdoor Block-Up Converter N Input (BUC)

AGILIS ALB229 160W Ku-Band VSAT Outdoor Block-Up Converter N Input (BUC)

AGILIS ALB229 160W Ku-Band VSAT Outdoor Block-Up Converter N Input (BUC)

IKtechcorp 是经销商用于 Agilis 卫星、vsat 通信产品。LNB、BUC、线路放大器、滤波器、隔离器、单元控制器、RF

这种小巧轻便的 BUC 是移动和卫星上行链路应用的理想选择。BUC 具有“同类最佳”效率和“最低功耗”。该装置适用于 96VAC 至 264VAC 的宽范围交流电源。创新和高效的热设计使该 BUC 成为业内最小、坚固、可靠和坚固的产品之一,足以承受户外条件。内置冗余功能消除了使用外部控制器进行 1:1 冗余操作的情况。

型号: agilisALB229N_160w

AGILIS ALB229 160W Ku-Band VSAT Outdoor Block-Up Converter N Input (BUC)

Agilis ALB 229 Series 160W BUC (Block Up Converter) Ku-Band N Input Connector Frequency Image Picture
Summary

This small and lightweight BUC is ideal for mobile and satellite uplink applications.

The BUC has “Best in Class” efficiency and “lowest power consumption.” The unit works on a wide range AC power supply of 96VAC to 264VAC. Innovative and efficient thermal design makes this BUC one of the smallest, robust, reliable and rugged enough to withstand outdoor conditions in the industry.

Built-in redundancy feature eliminates the use of an external controller for 1:1 redundancy operation. This eliminates messy cabling at the antenna making this a very elegant solution.Extensive M/C interface with RS232/RS485/Ethernet(SNMP & HTTP), and Wifi.

 
Features
• Compact and lightweight
• Available in standard and extended Ku-Band
• Forward & reverse power detection
• Input power detection
• Intuitive monitoring & control through RS232/RS485 &Ethernet (SNMP & HTTP), and Wifi.
• Automatic fault identification & alarm generation
• Temperature compensation facility
• Built-in redundancy facility
• Built-in 10MHz reference with auto-detection
• Built-in receive reject filter• Sample port for output monitoring
• Wide operating temperature range -40ºC to +60ºC
• RoHS Compliant
• Waterproof
 
Reliability
Field proven under harsh environment conditions, Agilis ODUs can withstand temperature ranging from -40ºC to +60ºC with up to 100% humidity.
 
Quality Assurance
100% of all BUCs go through stringent quality checks in addition to well defined Electrical Stress Screening to ensure operation in harsh outdoor environments.The BUCs are also subjected to seal test for water ingress verification.

AGILIS ALB229 160W Ku-Band VSAT Outdoor Block-Up Converter N Input (BUC) Specifications

RF Specifications

Transmit Frequency

14.0GHz - 14.5GHz

 

13.75GHz - 14.5GHz

IF Frequency Range

950MHz to 1450MHz

 

950MHz to 1700MHz

L0 Frequency

13.05GHz (Ku-Band)

 

12.8GHz (Extended Ku-Band)

Output Power Psat

53.0dBm

Output Power P1dB 52.0dBm
Rated Output Power 52.0dBm

Spectral Re-growth

30dBc @ Prated

Third Order Intermod (two tone)

-25dBc @ Relative to combine power of two carrier at 3dB total power back off from Rated Output Power.

Small Signal Gain

75dB Min

Gain Flatness Full Band

±2dB

Gain Slope over 40MHz

±1dB

Gain Variation over temperature

±1.0dB @ from -40ºC to +60ºC

Gain Control

20 dB in step of 0.5 dB

O/P spurious

According to EN301428

Phase Noise @ Offset

 

1KHz

-75dBc/Hz

10KHz

-85dBc/Hz

100KHz

-95dBc/Hz

I/P VSWR

1.3:1

O/P VSWR

1.25:1

Noise Power Density Tx BD

70dBW/4KHz

Rx BD

142dBW/4KHz

 

DC Power

Prime Power

230VAC (range 96V to 264VAC)

Power Consumption 80W / 100W

2000VA Typical

 

Interfaces

IF Input Interface 50Ohms N-type Female / 75Ohms F-type Female
Output Interface WR 75G
 

External Reference Requirement

Frequency

 

Power

 
Internal reference  

External reference phase

 

noise requirement @ frequency offset

 

1KHz

 

10KHz

 

100KHz

 
 

Monitor & Control

Monitor BUC temperature
Status alarm
Output power
Reverse power
Input power
LED status indication
   
Control Attenuation
RF output mute
   
Interface RS232/RS485 & Ethernet (SNMP & HTTP) WIFI
   
Tx Redundancy Built-in
 

Environmental

Operating Temperature -40ºC to +60ºC
Humidity Up to 100% Weather protection sealed to IP65
 

Mechanical

Size 80W / 100W

600L x 240W x 230H mm

Weight 80W / 100W

28kg

Color

White Powder Coat