欢迎来到 IK Tech Corporation
一站式满足您所有的卫星需求

VIKING ETI-ADH-NETCOM (23437) Automatic Air Dehydrator with Ethernet Communications AC Power

VIKING ETI-ADH-NETCOM (23437) Automatic Air Dehydrator with Ethernet Communications AC Power

VIKING ETI-ADH-NETCOM (23437) 带以太网通信交流电源的自动空气脱水器

IKtechcorp 是经销商Viking SATCOM 是商业卫星设备的领先制造商和供应商。Viking SATCOM 提供广泛的产品,用于 VSAT、DTH、COTM、移动、TVRO、教育、电信、有线和广播行业。卫星、DTH、VSAT 、飞行、快速部署、仅接收、地球站、RF、prodelin、机动自动点、车辆天线。还具有信标接收器、除冰系统、脱水器、馈送、过滤器、支架、冗余系统、雪盖等。”/></p> <p>• 带前显示面板选项的机架安装配置<br />• 100-240 VAC,</div>
                
                <div class=

型号: VIKING_ETI-ADH-NETCOM_23437

VIKING ETI-ADH-NETCOM (23437) Automatic Air Dehydrator with Ethernet Communications AC Power

VIKING ETI-ADH-NETCOM Automatic Air Dehydrator with Ethernet Communications - RACK MOUNT Product Picture, Price, Image, Pricing
 
Summary

VIKING ETI-ADH-NETCOM Automatic Air Dehydrator with Ethernet Communications

Waveguide Dehydrator: ADH NETCOM
The ADH NETCOM automatic waveguide dehydrator supplies low pressure dry air to keep waveguide and coaxial cable dry. Output pressure is configurable between 0.10 psig and 7.50 psig (7mbar – 517mbar) in 0.01 psig (0.67mbar) increments. Factory default pressure is 0.5 psig (34.5mbar). Operational monitoring and alarms are software based making them highly configurable in the field. Future software features can be installed while in service over the internet or local Ethernet network.

Network-ready
The ADH NETCOM automatic dehydrator is Ethernet network ready. Units can be configured and monitored using either built in SNMP support or the web interface. Legacy system support is provided via RS-422/485 or RS-232 interfaces. Three programmable alarm relays are also included. Communicated operational information includes output pressure, duty cycle, temperature, compressor hours and air drying canister status. The ADH NETCOM automatic dehydrator uses a brushless dual-diaphragm pump for long life. Dehydrator operates with exceptionally low noise and vibration levels. The air drying canisters use aluminum oxide desiccant for high efficiency. The humidity sensor signals for regeneration based upon current dew point rather than at fixed time intervals for additional energy savings and long desiccant life.

The ADH NETCOM automatic dehydrator requires only 5-1/4″ (3-U) of rack space and is just 12″ (304.8mm) deep. Mounting hardware allows for fl exible installation options including dual- and single-post rack mounting and wall mounting. The standard unit weighs just 16 lbs (7.26 kg).

The ADH NETCOM automatic dehydrator operates from 100-240 VAC, 50/60 Hz. The dehydrator consumes a maximum of 100 watts during regeneration and approximately 40 watts otherwise. Heat dissipated is up to 325 BTU/hr during regeneration and approximately 100 BTU/hr otherwise. This product creates an exceptionally low heat load for an automatic dehydrator.

Optional Front Panel Display
An optional front panel with display allows for IP configuration and status monitoring when no network is available.

VIKING ETI-ADH-NETCOM Automatic Air Dehydrator Features:

Provides dry pressurized air to ensure signal quality of antenna waveguide and dielectric coaxial cable
Highly configurable to meet the needs of wide ranging applications
Programmable operating pressure range: 0.10 psig - 7.50 psig (7mbar - 517mbar)
Brushless compressor for long life
Future-proof software based features allow updates and upgrades while in service
Remote monitoring and control with web interface or SNMP
Configurable Master/Slave operation
Ethernet, RS-422/485, RS-232 and alarm relay outputs for compatibility with nearly any system
Optional front panel with display allows for IP configuration and status monitoring when no network is available
Simple power connections for 100-240 VAC
Small, light weight chassis with multiple mounting options makes installation easy
Low energy use minimizes operational costs
Quiet operation
 

Configuration
 
VIKING ETI-ADH-NETCOM Automatic Air Dehydrator Conversion from rack mount to wall mount unit
 
 

VIKING ETI-ADH-NETCOM (23437) Automatic Air Dehydrator with Ethernet Communications AC Power

 

GENERAL

   
Approvals UL, CE
Regeneration Method Automatic, demand
Maximum dew point -40˚ F/C
 

ENCLOSURE

   
Dimensions 17″ × 12″ × 5-1/4″ (432mm × 305mm × 133mm)
Weight 16 lbs (7.26 kg)
Mounting Dual-post rack, flush mounted
Single-post rack, center mounted
Wall mounted
 

POWER

   
Supply 100-240 VAC, 50/60 Hz 
Maximum current 1.0 Amps at 100 V
Power usage 40 W typical, 100 W max
Heat dissipation 100 BTU/hr typical, 325 BTU/hr max
 

OUTPUT

   
Flow rate 25.4 scfh (12 lpm)
Maximum pressure 7.5 psig (517mbar)
Internal safety relief valve 8 psig (552mbar)
Discharge port 1/8″ NPT 
3/8″ or 1/4″ hose barb (both included)
Display units SI (millibars); English (psig), default
 

CONTROL

   
Protocols HTTP (Web Interface), SNMP, UDP, TFTP
Maximum pressure Confi gurable Range: 0.20 psig – 7.5 psig (14mbar – 517mbar), Default: 0.50 psig (34.5mbar)
Minimum pressure Confi gurable Range: 0.10 psig – 7.4 psig (7mbar – 510mbar), Default: 0.30 psig (21mbar)
Low pressure alarm level User Configurable, Default: 0.15 psig (10mbar)
High pressure alarm level User Configurable, Default 1.5 psig (103.5mbar)
Alarm relays Contact Type – Form C, SPDT, reverse acting 
Ratings – 0.25 Amps @ 60 V 
User configurable, Defaults:
  • Alarm Relay 1: Summary Alarm
  • Alarm Relay 2: Low Pressure Alarm
  • Alarm Relay 3: Over Pressure Alarm
Duty cycle alarm User configurable, Default: 50%
Master/Slave configuration User configurable, Default: Standard/Slave
 

ENVIRONMENTAL

   
Operating temperature 32°F to 130°F (0°C to 55°C)
Storage temperature −40°F to 150°F (−40°C to 60°C)
 

Diagrams

 
VIKING ETI-ADH-NETCOM Automatic Air Dehydrator with Ethernet Communications - RACK MOUNT Mechanical Diagram Drawing
 
New Japan Radio NJRC NJT8301N 1.5W Ku-Band (Standard 14.0 to 14.5 GHz) Block Up Converter BUC N-Type Connector Input Mechanical Diagram Drawing
 